B1285 ProTalk Link
The ProTalk Link provides a flexible, effective solution to a wide variety of alarm monitoring situations. Each system consists of one main module and at least one communication module. The systems can be further expanded using any combination of the available digital, analog or PLC expansion modules. Alarm notifications can be sent via phone, text, email, radio or PA system. Remote alarm acknowledgement, system interrogation and relay control is possible via phone and text.
Highlights
- Two communication modules enable you to send critical alarm messages over any combination of mobile radio, telephone, cellular (LTE, HSPA), paging or electronically in the form of SMS text or Email
- Three expansion modules enable you to expand the ProTalk Link to over 500 alarm points
- Monitor Modbus, Allen Bradley, and EtherNet/IP PLCs via RS232, RS485 and TCP/IP
- Local and Internet real-time alarm viewing
One M1 Module is required for each Link System and is the master control unit.
Model #: B1285-M1
General Features
Display
- Indicator LEDs and connector markings
Inputs and Outputs
- 2 dedicated inputs for Power Fail Alarm and Acknowledge Alarms
- 2 Form C relays, 1 A at 30 VDC
- Plug-in screw terminal block accepts AWG 26 to 12 wire
Program Ports
- DB9, RS232 serial - used for programming, code updating and monitoring unit status
- USB - Equivalent functions as DB9
- Tel - RJ11 connects to DTMF capable phone for voice recording and programming
Voice Storage
- Flash memory, 60 minute voice storage capacity with up to 521 user recordable voices
Specifications Download Specs
Power
- +10 VDC to +30 VDC, 150 mA at 12 VDC, 100 mA at 24 VDC with all indicators on
Environment
- -40°C to +60°C, 0 to 95% humidity, non-condensing
Physical
- 8.9" x 2.42" x 4.32"
Rating
- CSA/UL Safety Approvals
NEMA Enclosure
|
|
Battery Backup Power Supply
|
|
Rack Mount Brackets
|
Communication Modules:
Model #: B1285-T1
- Telephone line(RJ11) and Radio port connection
- Announce alarms over any combination of telephone,radio or PA (public address) system
- Can be used in conjunction with a cellular module as a backup callout
- Modem can be used for remote programming with PC software
General Features
Display
- Indicator LEDs and connector markings
Inputs and Outputs
- 8 ground closure operation inputs
- Inputs programmable as Digital, Totalizer, Interval Timer, or Accumulator alarm types
- 4 total Outputs, Form C relay. 2 A at 30 VDC rated
- Plug-in screw terminal block accepts AWG 26 to 12 wire
Ports
- Radio: TX audio: 600 Ω single ended capacitively coupled
- Radio: RX audio: 10 kΩ single ended capacitively coupled
- Telephone: RJ11, Dial or Pulse. POTS interface. Modem connectivity at 14,400bps
Specifications Download Specs
Power
- +10 VDC to +30VDC, 150 mA at 12 VDC, 100 mA at 24 VDC with all indicators on
Environment
- -40°C to +60°C, 0 to 95% humidity, non-condensing
Physical
- 8.9" x 2.42" x 4.32"
Rating
- CSA/UL Safety Approvals
Telephone Line Transient Protector
|
Model #: B1285-W4
- Provides a cellular based phone connection via integrated LTE/HSPA module
- Send voice alarms, SMS text, and Email messages
- New Email reporting feature
- Can be used in conjunction with a Telephone Module for a backup callout
General Features
Display
- Indicator LEDs and connector markings
Inputs and Outputs
- 8 ground closure operation inputs
- Inputs programmable as Digital, Totalizer, Interval Timer, or Accumulator alarm types
- 4 total Outputs, Form C relay. 2 A at 30 VDC rated
- Plug-in screw terminal block accepts AWG 26 to 12 wire
Ports
- Antenna: SMA female. 50 ohm
Specifications Download Specs
Power
- +10 VDC to +30 VDC, 150mA at 12 VDC, 100 mA at 24 VDC with all indicators on
Power When Transmitting
- add 500 mA at 12 VDC or 300 mA at 24 VDC
Environment
- -40°C to +60°C, 0 to 95% humidity, non-condensing
Physical
- 8.9" x 2.42" x 4.32"
Rating
- CSA/UL Safety Approvals
SIM Card
- Mini-SIM, 25.00mm x 15.00mm x 0.76mm
LP Dual Band Antenna
|
|
Phantom Dual Band Antenna
|
|
Dual Band Omni-Directional Antenna
|
|
|
|
35' Lightning Protector to Antenna N to N Cable
|
|
6' B1285-W To Lightning Protector SMA to N Cable
|
Expansion Modules:
Model #: B1285-P2
- Connect with PLC's using Modbus, Allen-Bradley and EtherNet/IP protocols
- Monitor up to 512 points
- Run multiple protocols simultaneously
General Features
Display
- Indicator LEDs and connector markings
Protocols
- Modbus RTU; master or slave (RS232 or RS485)
- Modbus TCP/IP; master or slave
- Allen Bradley DF1; Master (point to point) to a PLC5 or SLC500 series device
- EtherNet/IP; Remote IO Adapter
Ports
- RS232 (DTE) DB9
- RS485
- Ethernet
Specifications Download Specs
Power
- +10 VDC to +30 VDC, 350 mA @ 10 VDC, with all indicators on
Environment
- -40°C to +60°C, 0 to 95% humidity, non-condensing
Physical
- 8.9" x 2.42" x 4.32"
Rating
- CSA/UL Safety Approvals
Model #: B1285-A1
General Features
Display
- Indicator LEDs and connector markings
Inputs
- 8 current loop inputs (4-20 mA). Impedance: 100 Ω floating. Max common voltage: +35 VDC.
- 8 voltage inputs (5-30 VDC). impedance: 100 kΩ to ground. Max input voltage: +35 VDC
- Plug-in screw terminal block accepts AWG 26 to 12 wire
Specifications Download Specs
Power
- +10 VDC to +30 VDC, 150 mA at 12 VDC, 100 mA at 24 VDC with all indicators on
Environment
- -40°C to +60°C, 0 to 95% humidity, non-condensing
Physical
- 8.9" x 2.42" x 4.32"
Rating
- CSA/UL Safety Approvals
Model #: B1285-D1
General Features
Display
- Indicator LEDs and connector markings
Inputs
- 16 digital inputs using ground closures or voltage closures ranging from 5 to 30 VDC
- 4 reset inputs used to reset totalizer or accumulator status
- Plug-in screw terminal block accepts AWG 26 to 12 wire
Specifications Download Specs
Power
- +10 VDC to +30 VDC, 150 mA at 12 VDC, 100 mA at 24 VDC with all indicators on
Environment
- -40°C to +60°C, 0 to 95% humidity, non-condensing
Physical
- 8.9" x 2.42" x 4.32"
Rating
- CSA/UL Safety Approvals
About the ProTalk Link
The ProTalk Link is a modular alarm auto dialer. Cellular dialing, SMS text, public address announcements, PLC integration, remote programming, callout redundancy, expansion capabilities - ALL are possible with the ProTalk Link.
In its simplest form, the ProTalk Link consists of one B1285-M1 control module and one communications module (B1285-T1 - landline or B1285-W4 - cellular). This setup will provide you with a callout, 8 discrete inputs and 4 relay outputs. You can add a complimentary communications module to provide backup alarm dialing in the event of a primary failure. Your choice in communications module will determine your available callout methods - landline calls & PA announcements OR cellular calls, SMS text & email.
Complex systems require flexibility. You can further expand the ProTalk Link using any combination of our 3 available expansion modules to a maximum of 16 total modules. The B1285-D1 Digital expansion module provides 16 discrete inputs and 4 reset inputs allowing you to reset the status of any totalizer or accumulator inputs. The B1285-A1 Analog expansion module provides 8 current loop inputs (4-20mA) and 8 voltage inputs (0-30V). The B1285-P2 PLC expansion module offers the most in terms of inputs (up to 480 points). Choose from a variety of protocols including Modbus RTU or TCP/IP, Allen Bradley DF1 or Ethernet/IP.
Operation of the ProTalk Link is similar to other units in the ProTalk line of alarm dialers.
When an alarm condition occurs, such as, high or low temperature, power failure or equipment upset, the ProTalk Link automatically places calls to inform people of the situation. In the case of unanswered calls, the ProTalk Link will continue to dial through a list of programmed numbers until it successfully reaches someone and is able to report the alarm.
The B1285 ProTalk Link is very versatile and can be programmed to perform many more functions at the discretion of the user. It can:
- announce alarms over telephone, text, radio, PA, email or any combination thereof.
- be programmed to send coded tones along with the voice messages to activate such devices as radio pagers, relay and annunciator panels.
- perform remote control functions automatically by using up to 10 relay outputs or manually by receiving user defined DTMF codes.
- use up to 8 alarm groups and 8 shifts to organize alarm callouts based on common alarms or time of day.
- be customized to suit most applications using a combination of callout units and expansion modules
- accepts both cellular and land line callout modules to provide reporting redundancy
- announce a module failure in the event of a B1285-M1 main module failure using autonomous mode
- email a daily activity summary report to notify you of all recorded activity
- email and/or text notifications when alarms are announced, cleared and/or acknowledged (for informational purposes only).
- email, text and/or phone regular status reports including alarm status and enabled point values
- define security levels for incoming calls and text messages.
- require an access code for phone or text access to programming.
- function in extreme temperatures of -40°C to +60°C (-40°F to 140°F).
The ProTalk Link brings the most in application compatibility and customization and continues the ProTalk trend of industry leading industrial alarm dialers.
Technical Documents
NEMA Enclosure
|
|
Battery Backup Power Supply
|
|
Rack Mount Brackets
|
|
Telephone Line Transient Protector
|
|
LP Dual Band Antenna
|
|
Phantom Dual Band Antenna
|
|
Dual Band Omni-Directional Antenna
|
|
|
|
35' Lightning Protector to Antenna N to N Cable
|
|
6' B1285-W To Lightning Protector SMA to N Cable
|
Applications & Industries
- Water / Wastewater
- Lift Station
- Compressor Sites